Entries Tagged as 'Field Controls'

Product: 9″ Automatic GVD Vent Damper
Manufacturer: Field Controls
Part Number: GVD-9PL
Weight: 3
Price: 134.95
Special: Free Shipping on Orders Over 0
Description: The Field Vent Damper works automatically to allow natural draft during appliance operation while preventing residual appliance heat and conditioned air from escaping during off cycles. It also prevents the infiltration of cold air during down drafts. Safety Features Dual safety switches allow the burner to fire only when the damper is in the open position. This unit will not interfere with existing appliance safety controls, when properly installed. Operational Features Operates with all 24 VAC, 60hz intermittent ignition and standing pilot ignition systems. Stainless steel construction provides superior corrosion resistance. Damper operation: power opens in 15 seconds, power closes in 15 seconds. Power is off at damper motor when it is at rest. Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems. Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection. Dimensions Pipe Size: 9″ Length: 10-1/8″ Height: 13-7/8″ Clearance: 3″ Exposed Pipe: 8-7/8″ How the GVD Works The Field Vent Damper is installed in the vent pipe, after the draft hood, or barometric. During off cycles, it remains closed, preventing air flow through the vent. When there is a call for heat, the motor is energized, rotating the damper 90 degrees to an open position. Opening and closing takes approximately 15 seconds. When the damper is fully open, the burner is allowed to fire and flue gases pass freely through the vent. When the thermostat is satisfied, the burner stops, and the damper automatically closes. For service and trouble shooting, the damper can be locked in the open position. Electrical Specifications Minimum wiring requirements: 24 VAC – 18 gauge – 105 degrees C Power requirements: 3 watts at 24 VAC, 60 Hz, when opening or closing


Tags: Field Controls

Product: UV-12, UV-Aire Purification System
Manufacturer: Field Controls
Part Number: UV-12
Weight: 2
Price: 144.95
Special: Free Shipping on Orders Over 0
Description: Features Minimum Duct Width: 9″ Voltage: 120 Amps: .5 Hz: 60 Watts: 30 Recommended Max. Sq. Ft.: 1500 Lamp Intensity at 1 meter µW/cm2: 37 Product Warranty: 18 months Installation 1. Insert the unit downstream from an A-coil in the supply plenum or downstream from the air filter in the return plenum. Mount base on duct using the enclosed mounting screws. 2. Insert lamp through hole. Place bracket over end of tube and tighten wing nut. 3. Replace cover on unit and tighten side screw. 4. Plug into 120V outlet & place rocker switch in “ON” position. 5. Switch will illuminate & blue glow can be seen through view port when unit is operating properly. How The In-duct UV-Aire Works UV-Aire uses the energy from a specially designed, high-intensity UV-C lamp to reduce microorganisms in the entire home as they cycle through the HVAC system. Mounted inside the ductwork, the UV-Aire sterilizes or kills most contaminants as they pass the lamp. The process requires very little maintenance and costs just pennies a day to operate. The UV-Aire could be one of the best health and comfort investments a homeowner ever makes. Indoor Air Treatment With UV UV s effectiveness in killing bacteria is directly related to a microorganism s exposure time. Indoor air in a typical residential forced-air HVAC system will be recirculated 40-75 times a day. With a UV generating lamp mounted in the HVAC duct, cumulative exposure can be very effective in controlling indoor bacteria. UV rays will also kill germs that breed in drain pans and A-coils. Properly positioned, an ultraviolet system can significantly reduce indoor air contamination and prevent the growth of new microorganisms. The treatment of indoor air with ultraviolet radiation has been successful in health care facilities, food processing plants, schools, laboratories and other applications. It is safe, silent, and proven. Since direct exposure to UV light can cause skin cancer and blindness, the most practical application of UV light in the home or office is in the main air distribution (heating and/or air conditioning) system. As UV light will not pass through metal, glass, or plastic, a UV light can be installed in the main supply or return duct of a central heating or air system without concern for direct exposure to eyes or skin. This is an ideal location since the air in the home or office will pass through the HVAC system up to 75 times per day during normal operation, and as many as 150 times per day in continuous fan mode.


Tags: Field Controls

Product: 10″ Automatic GVD Vent Damper
Manufacturer: Field Controls
Part Number: GVD-10PL
Weight: 3
Price: 144.95
Special: Free Shipping on Orders Over 0
Description: The Field Vent Damper works automatically to allow natural draft during appliance operation while preventing residual appliance heat and conditioned air from escaping during off cycles. It also prevents the infiltration of cold air during down drafts. Safety Features Dual safety switches allow the burner to fire only when the damper is in the open position. This unit will not interfere with existing appliance safety controls, when properly installed. Operational Features Operates with all 24 VAC, 60hz intermittent ignition and standing pilot ignition systems. Stainless steel construction provides superior corrosion resistance. Damper operation: power opens in 15 seconds, power closes in 15 seconds. Power is off at damper motor when it is at rest. Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems. Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection. Dimensions Pipe Size: 10″ Length: 12-1/8″ Height: 14-7/8″ Clearance: 4″ Exposed Pipe: 10-7/8″ How the GVD Works The Field Vent Damper is installed in the vent pipe, after the draft hood, or barometric. During off cycles, it remains closed, preventing air flow through the vent. When there is a call for heat, the motor is energized, rotating the damper 90 degrees to an open position. Opening and closing takes approximately 15 seconds. When the damper is fully open, the burner is allowed to fire and flue gases pass freely through the vent. When the thermostat is satisfied, the burner stops, and the damper automatically closes. For service and trouble shooting, the damper can be locked in the open position. Electrical Specifications Minimum wiring requirements: 24 VAC – 18 gauge – 105 degrees C Power requirements: 3 watts at 24 VAC, 60 Hz, when opening or closing


Tags: Field Controls

Product: 12″ Automatic GVD Vent Damper
Manufacturer: Field Controls
Part Number: GVD-12PL
Weight: 3
Price: 152.95
Special: Free Shipping on Orders Over 0
Description: The Field Vent Damper works automatically to allow natural draft during appliance operation while preventing residual appliance heat and conditioned air from escaping during off cycles. It also prevents the infiltration of cold air during down drafts. Safety Features Dual safety switches allow the burner to fire only when the damper is in the open position. This unit will not interfere with existing appliance safety controls, when properly installed. Operational Features Operates with all 24 VAC, 60hz intermittent ignition and standing pilot ignition systems. Stainless steel construction provides superior corrosion resistance. Damper operation: power opens in 15 seconds, power closes in 15 seconds. Power is off at damper motor when it is at rest. Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems. Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection. Dimensions Pipe Size: 12″ Length: 12-1/8″ Height: 16-7/8″ Clearance: 4″ Exposed Pipe: 10-7/8″ How the GVD Works The Field Vent Damper is installed in the vent pipe, after the draft hood, or barometric. During off cycles, it remains closed, preventing air flow through the vent. When there is a call for heat, the motor is energized, rotating the damper 90 degrees to an open position. Opening and closing takes approximately 15 seconds. When the damper is fully open, the burner is allowed to fire and flue gases pass freely through the vent. When the thermostat is satisfied, the burner stops, and the damper automatically closes. For service and trouble shooting, the damper can be locked in the open position. Electrical Specifications Minimum wiring requirements: 24 VAC – 18 gauge – 105 degrees C Power requirements: 3 watts at 24 VAC, 60 Hz, when opening or closing


Tags: Field Controls

Product: 4″ Automatic GVD Vent Damper
Manufacturer: Field Controls
Part Number: GVD-4PL
Weight: 3
Price: 93.95
Special: Free Shipping on Orders Over 0
Description: The Field Vent Damper works automatically to allow natural draft during appliance operation while preventing residual appliance heat and conditioned air from escaping during off cycles. It also prevents the infiltration of cold air during down drafts. Safety Features Dual safety switches allow the burner to fire only when the damper is in the open position. This unit will not interfere with existing appliance safety controls, when properly installed. Operational Features Operates with all 24 VAC, 60hz intermittent ignition and standing pilot ignition systems. Stainless steel construction provides superior corrosion resistance. Damper operation: power opens in 15 seconds, power closes in 15 seconds. Power is off at damper motor when it is at rest. Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems. Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection. Dimensions Pipe Size: 4″ Length: 6-1/16″ Height: 8-7/8″ Clearance: 15/16″ Exposed Pipe: 4-13/16″ How the GVD Works The Field Vent Damper is installed in the vent pipe, after the draft hood, or barometric. During off cycles, it remains closed, preventing air flow through the vent. When there is a call for heat, the motor is energized, rotating the damper 90 degrees to an open position. Opening and closing takes approximately 15 seconds. When the damper is fully open, the burner is allowed to fire and flue gases pass freely through the vent. When the thermostat is satisfied, the burner stops, and the damper automatically closes. For service and trouble shooting, the damper can be locked in the open position. Electrical Specifications Minimum wiring requirements: 24 VAC – 18 gauge – 105 degrees C Power requirements: 3 watts at 24 VAC, 60 Hz, when opening or closing


Tags: Field Controls

Product: 5″ Automatic GVD Vent Damper
Manufacturer: Field Controls
Part Number: GVD-5PL
Weight: 3
Price: 97.75
Special: Free Shipping on Orders Over 0
Description: The Field Vent Damper works automatically to allow natural draft during appliance operation while preventing residual appliance heat and conditioned air from escaping during off cycles. It also prevents the infiltration of cold air during down drafts. Safety Features Dual safety switches allow the burner to fire only when the damper is in the open position. This unit will not interfere with existing appliance safety controls, when properly installed. Operational Features Operates with all 24 VAC, 60hz intermittent ignition and standing pilot ignition systems. Stainless steel construction provides superior corrosion resistance. Damper operation: power opens in 15 seconds, power closes in 15 seconds. Power is off at damper motor when it is at rest. Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems. Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection. Dimensions Pipe Size: 5″ Length: 6-1/16″ Height: 9-7/8″ Clearance: 15/16″ Exposed Pipe: 4-13/16″ How the GVD Works The Field Vent Damper is installed in the vent pipe, after the draft hood, or barometric. During off cycles, it remains closed, preventing air flow through the vent. When there is a call for heat, the motor is energized, rotating the damper 90 degrees to an open position. Opening and closing takes approximately 15 seconds. When the damper is fully open, the burner is allowed to fire and flue gases pass freely through the vent. When the thermostat is satisfied, the burner stops, and the damper automatically closes. For service and trouble shooting, the damper can be locked in the open position. Electrical Specifications Minimum wiring requirements: 24 VAC – 18 gauge – 105 degrees C Power requirements: 3 watts at 24 VAC, 60 Hz, when opening or closing


Tags: Field Controls

Product: 6″ Oil Vent Damper
Manufacturer: Field Controls
Part Number: OVD-6
Weight: 5
Price: 154.95
Special: Free Shipping on Orders Over 0
Description: Benefits Reduces heating bill Improves efficiency Increases comfort Reduces off-cycle heat loss Features Available in sizes 4″– 8″ Blocked vent safety switch included Automatic power open/power close Two internal safety switches Flex seal provides self cleaning action Hold open service switch Stainless steel construction CSA listed (Listed to UL-17 Standard and CSA B140.14)

Tags: Field Controls

Product: 4″ Oil Vent Damper
Manufacturer: Field Controls
Part Number: OVD-4
Weight: 5
Price: 154.95
Special: Free Shipping on Orders Over 0
Description: Benefits Reduces heating bill Improves efficiency Increases comfort Reduces off-cycle heat loss Features Available in sizes 4″– 8″ Blocked vent safety switch included Automatic power open/power close Two internal safety switches Flex seal provides self cleaning action Hold open service switch Stainless steel construction CSA listed (Listed to UL-17 Standard and CSA B140.14)

Tags: Field Controls

Product: 6″ Automatic GVD Vent Damper
Manufacturer: Field Controls
Part Number: GVD-6PL
Weight: 3
Price: 98.95
Special: Free Shipping on Orders Over 0
Description: The Field Vent Damper works automatically to allow natural draft during appliance operation while preventing residual appliance heat and conditioned air from escaping during off cycles. It also prevents the infiltration of cold air during down drafts. Safety Features Dual safety switches allow the burner to fire only when the damper is in the open position. This unit will not interfere with existing appliance safety controls, when properly installed. Operational Features Operates with all 24 VAC, 60hz intermittent ignition and standing pilot ignition systems. Stainless steel construction provides superior corrosion resistance. Damper operation: power opens in 15 seconds, power closes in 15 seconds. Power is off at damper motor when it is at rest. Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems. Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection. Dimensions Pipe Size: 6″ Length: 6-1/2″ Height: 10-7/8″ Clearance: 1-3/16″ Exposed Pipe: 5-1/4″ How the GVD Works The Field Vent Damper is installed in the vent pipe, after the draft hood, or barometric. During off cycles, it remains closed, preventing air flow through the vent. When there is a call for heat, the motor is energized, rotating the damper 90 degrees to an open position. Opening and closing takes approximately 15 seconds. When the damper is fully open, the burner is allowed to fire and flue gases pass freely through the vent. When the thermostat is satisfied, the burner stops, and the damper automatically closes. For service and trouble shooting, the damper can be locked in the open position. Electrical Specifications Minimum wiring requirements: 24 VAC – 18 gauge – 105 degrees C Power requirements: 3 watts at 24 VAC, 60 Hz, when opening or closing


Tags: Field Controls

Product: 7″ Automatic GVD Vent Damper
Manufacturer: Field Controls
Part Number: GVD-7PL
Weight: 3
Price: 103.95
Special: Free Shipping on Orders Over 0
Description: The Field Vent Damper works automatically to allow natural draft during appliance operation while preventing residual appliance heat and conditioned air from escaping during off cycles. It also prevents the infiltration of cold air during down drafts. Safety Features Dual safety switches allow the burner to fire only when the damper is in the open position. This unit will not interfere with existing appliance safety controls, when properly installed. Operational Features Operates with all 24 VAC, 60hz intermittent ignition and standing pilot ignition systems. Stainless steel construction provides superior corrosion resistance. Damper operation: power opens in 15 seconds, power closes in 15 seconds. Power is off at damper motor when it is at rest. Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems. Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection. Dimensions Pipe Size: 7″ Length: 7-1/16″ Height: 11-7/8″ Clearance: 1-7/16″ Exposed Pipe: 5-13/16″ How the GVD Works The Field Vent Damper is installed in the vent pipe, after the draft hood, or barometric. During off cycles, it remains closed, preventing air flow through the vent. When there is a call for heat, the motor is energized, rotating the damper 90 degrees to an open position. Opening and closing takes approximately 15 seconds. When the damper is fully open, the burner is allowed to fire and flue gases pass freely through the vent. When the thermostat is satisfied, the burner stops, and the damper automatically closes. For service and trouble shooting, the damper can be locked in the open position. Electrical Specifications Minimum wiring requirements: 24 VAC – 18 gauge – 105 degrees C Power requirements: 3 watts at 24 VAC, 60 Hz, when opening or closing


Tags: Field Controls